Regenerative power supply modules
Rated data
Operation at rated mains voltage 230 V
6
290
EDS94SPP101 EN 10.2
6.3.2 Operation at rated mains voltage 230 V
Input data (on the supply side)
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 230 180 − 0 % ... 264 + 0 % 45 − 0 % ... 65 + 0 %
Voltage Continuous input power
Type [V] S
L
[kVA]
E94ARNE0134
In motor mode
230 10.3
In generator mode
230 5.2
E94ARNE0244
In motor mode
230 18.7
In generator mode
230 9.4
Output data (on the DC side)
Mains Volta
e Volta
e ran
e Fre
uenc
ran
e
U
DC
[V]
U
DC
[V]
f [Hz]
2/PE DC 325 260 − 0 % ... 370 + 0 % −
Output current and output power
100 % 5−s cycle 3−min cycle
Type I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW] I
DC
[A] P
DC
[kW]
E94ARNE0134
In motor mode
32 8.6 96 25.8 48 12.9
In generator mode
16 4.3 48 12.9 24 6.4
E94ARNE0244
In motor mode
57 15.6 171 46.6 86 23.3
In generator mode
28.5 7.8 87 23.3 44 11.6
100 % Permanent rated values
5−s cycle Cycle for the second−range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)
3−min cycle Cycle for the minute−range