5. PARAMETERS
5.11 (A) Application parameters
3
4
5
5
5
6
7
8
9
10
5.11 (A) Application parameters
Purpose Parameter to set Refer to
page
To operate by switching between the
inverter and the commercial power
supply operation
Electronic bypass function P.A000 to P.A005 Pr.135 to Pr.139,
Pr.159
376
To reduce the standby power Self power management P.A002, P.A006,
P.A007, P.E300
Pr.30, Pr.137, Pr.248,
Pr.254
385
To count the number of inverter
startups
Start count monitor P.A170, P.A171 Pr.1410, Pr.1411 388
To strengthen or weaken the
frequency at a constant cycle
Traverse operation P.A300 to P.A305 Pr.592 to Pr.597 389
To remove stains on the impellers or
fans of pumps by repeating a
forward/reverse rotation
Cleaning function P.A420 to P.A430 Pr.1469 to Pr.1479 391
To perform process control, such as
for the pump flow volume and air
volume
Multi-pump function
(Advanced PID function)
P.A400 to P.A414,
P.A442
Pr.578 to Pr.591,
Pr.1370, Pr.1376
429
PID pre-charge function P.A616 to P.A620,
P.A626, P.A656 to
P.A660, P.A666
Pr.760 to Pr.769,
Pr.1132, Pr.1133
424
PID display adjustment P.A600, P.A630 to
P.A633, P.A670 to
P.A673
Pr.759, Pr.934,
Pr.935, Pr.1136 to
Pr.1139
421
PID control P.A442, P.A457,
P.A601 to P.A607,
P.A610 to P.A615,
P.A621 to P.A625,
P.A640 to P.A644,
P.A650 to P.A655,
P.A661 to P.A665,
P.A683 to P.A689
Pr.127 to Pr.134,
Pr.553, Pr.554,
Pr.575 to Pr.577,
Pr.609, Pr.610,
Pr.753 to Pr.758,
Pr.1015, Pr.1134,
Pr.1135, Pr.1140,
Pr.1141, Pr.1143 to
Pr.1149, Pr.1346,
Pr.1370, Pr.1460 to
Pr.1466
396
PID control enhanced functions P.A440 to P.A457,
P.A627 to P.A629,
P.F031
Pr.111, Pr.1346,
Pr.1361 to Pr.1375,
Pr.1377 to Pr.1381
440
To set the constant optimal for PID
control
PID gain tuning P.A690 to P.A698 Pr.1211 to Pr.1219 415
To continue operating at analog
current input loss
4 mA input check P.A680 to P.A682 Pr.573, Pr.777,
Pr.778
338
To restart without stopping the motor
at instantaneous power failure
Automatic restart after
instantaneous power failure /
flying start function for
induction motors
P.A700 to P.A705,
P.A710, P.F003
Pr.57, Pr.58, Pr.162
to Pr.165, Pr.299,
Pr.611
448
Frequency search accuracy
improvement (V/F control,
offline auto tuning)
P.A700, P.A711,
P.A712, P.C110,
P.C210
Pr.96, Pr.162, Pr.298,
Pr.463, Pr.560
454
To decelerate the motor to a stop at
instantaneous power failure
Power failure time
deceleration-to-stop function
P.A730 to P.A735,
P.A785
Pr.261 to Pr.266,
Pr.294
45
8
To operate with sequence program PLC function P.A800 to P.A805,
P.A811 to P.A859
Pr.414 to Pr.417,
Pr.498, Pr.675,
Pr.1150 to Pr.1199
463
To store the inverter running status
to a USB memory device
Trace function P.A900 to P.A906,
P.A910 to P.A920,
P.A930 to P.A939
Pr.1020 to Pr.1047 466

Table of Contents

Other manuals for Mitsubishi Electric FR-F846-00023-L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric FR-F846-00023-L2 and is the answer not in the manual?

Mitsubishi Electric FR-F846-00023-L2 Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-F846-00023-L2
CategoryInverter
LanguageEnglish

Related product manuals