3.4 Backup/Restoration
3 - 9
3
SPECIAL FUNCTION SETTING
3.4 Backup/Restoration
3.4.1 Backup/restoration setting
The storage location for backup data can be set.
For how to use the backup/restoration, refer to the following.
âž GOT2000 Series User's Manual (Monitor)
Set the following items with touching the items on the GOT.
Item Description Setting range
Drive for backup setting
The drive for storing backup settings, including parameters and passwords
for controllers, can be selected.
A: Built-in SD card
B: USB Drive
C: Flash Memory
E: USB Drive
F: USB Drive
G: USB Drive
<Default: A: Built-in SD card>
Drive for backup data The drive for storing backup data can be selected.
A: Built-in SD card
B: USB Drive
C: Flash Memory
E: USB Drive
F: USB Drive
G: USB Drive
<Default: A: Built-in SD card>
Trigger backup setting
The GOT automatically backs up data when triggers (Rise, Time) specified
for each backup setting are met.
None/Rise/Time
<Default: None>
âž 3.5 Trigger Backup
Max. of backup data
Set the maximum number of backup data to be stored.
(When 0 is specified, the GOT does not check the number of backup data to
be stored.)
Setting range: 0 to 50
<Default: 0>
Enable CPU No. setting
Set whether to specify the CPU No. at a backup.
(When [YES] is selected, the GOT starts to communicate with only the
specified PLC. Therefore the network batch backup/restoration on the
multiple PLCs cannot be executed.)
YES/NO
<Default: NO>
Retain file register inf.
during restor
Set whether to retain the file register information at a restoration.
YES/NO