2 - 72
2.14 Operator Authentication
2.14.3 Function setting
â– 1. Function setting
(1) Function setting function
The functions for the operator information can be set.
The following items can be set.
(2) Display operation of function setting
Item Description Reference
Automatic logout time
The time from when the last time the GOT is operated until when you
automatically log out of the GOT can be set. (1 to 60 minutes, 0 is invalid.)
(a) Automatic logout time
Auth method
The authentication method can be switched. ([Operator name + password],
[External auth (general)])
When [External auth (general)] is selected, the check box for [Operator
name + password] appears.
(b) Authentication method
Password expiration date
Set the item for regularly changing the password to be used for the
operator authentication. (1 to 1000 days, 0 is invalid.)
When the password is out of date after setting the password, the GOT
requests the password change.
(c) Password expiration date
Initial position input
Set the initial position input (byte count) of external authentication ID from
among the data read from the external authentication device. (0 to 1998
bytes)
(d) Initial position input
Valid byte count input Set the valid byte count for external authentication ID. (2 to 16 bytes) (e) Valid byte count input
Upon login failure, prohibit
login for a set period of time
Set the continuous failure count to block login. (3 to 10 times, 0: invalid)
Set the prohibition time. (1 to 3600 seconds)
(f) Continuous failure count to
block login
(g) Login prohibition time
Upon login failure, lock the
operator (individually)
Set the continuous failure count to lock an operator ID. (3 to 10 times, 0:
invalid)
(h) Continuous failure count to
lock an operator ID
Function setting
GOT basic setting
Operator authentication
Touch
[Function setting].
Touch
[Operator
authentication].