5-21
5
îš‹ Motor Parameters: E
V/f Pattern 1: E1
Param
eter
Num-
ber
Name
Description
Set-
ting
Range
Fac-
tory
Setting
Chang
e dur-
ing
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
E1-01
Input voltage
setting
Sets the Inverter input voltage.
This setting is used as a reference
value for protection functions.
310 to
510
*1
*1. The given values are for a 400 V Class Inverter.
400 V
*1
No Q Q Q Q 300H
6-59
6-62
Input
Voltage
E1-04
Max. output fre-
quency
(FMAX)
To set V/f characteristics in a straight
line, set the same values for E1-07 and
E1-09. In this case, the setting for E1-
08 will be disregarded.
Always ensure that the four frequen-
cies are set in the following manner:
E1-04 (FMAX) ≥ E1-06 (FA) > E1-07
(FB) ≥ E1-09 (FMIN)
40.0 to
120.0
i
No
Q
50.00
Hz
Q
50.00
Hz
Q
50.00
Hz
-
303H
6-59
6-62
Max Frequency
(PG-
F2)
0 to
1200
-- -
Q
150
rpm
(PG-
X2)
0 to
3600
E1-05
Max. output
voltage
(VMAX)
0.0 to
510.0
*1
380.0
V
*1
No Q Q Q - 304H 6-59
Max Voltage
E1-06
Base frequency
(FA)
0.0 to
120.00
i
No
Q
50.00
Hz
Q
50.00
Hz
Q
50.00
Hz
-
305H
6-59
6-62
Base Frequency
20 to
7200
rpm
-- -
Q
150
rpm
E1-07
Mid. output fre-
quency (FB)
0.0 to
120.0
3.0 Hz No A A - - 306H 6-59
Mid Frequency
A
E1-08
Mid. output fre-
quency voltage
(VB)
0.0 to
510
*1
i
No
Q
37.3
V
*1
Q
25.0
V
*1
- - 307H 6-59
Mid Voltage A
E1-09
Min. output fre-
quency (FMIN)
0.0 to
120.0
i
No
Q
0.5
Hz
Q
0.3 Hz
A
0.0 Hz
-
308H
6-59
6-62
Min Frequency
0 to
7200
No - - -
A
0 rpm
E1-10
Min. output fre-
quency voltage
(VMIN)
0.0 to
510.0
*1
i
No
Q
19.4
V
*1
Q
5.0 V
*1
- - 309H 6-59
Min Voltage
E1-13
Base voltage
(VBASE)
Sets the output voltage of the base fre-
quency (E1-06).
0.0 to
510.0
*1
i
*2
*2. E1-13 is set to the same value as E1-05 by autotuning.
No
A
0.0 V
A
0.0V
-
Q
200 V
30CH 6-59
Base Voltage
Output Voltage (V)
Frequency (Hz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron VARISPEED L7 and is the answer not in the manual?

Omron VARISPEED L7 Specifications

General IconGeneral
BrandOmron
ModelVARISPEED L7
CategoryInverter
LanguageEnglish

Related product manuals