EasyManuals Logo
Home>Omron>Inverter>VARISPEED L7

Omron VARISPEED L7 User Manual

Omron VARISPEED L7
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
5-12
5
Tuning Parameters: C
Acceleration/Deceleration: C1
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
C1-01
Acceleration time 1
Sets the acceleration time to
accelerate from 0 Hz to the
maximum output frequency.
0.00 to
600.00
*1
*1. The setting range for acceleration/deceleration times depends on the setting of C1-10. If C1-10 is set to 1, the setting range for acceleration/deceleration
times becomes 0.0 to 6000.0 seconds.
1.50 s
Yes Q Q Q Q 2 00H 6-20
Accel Time 1
C1-02
Deceleration time 1
Sets the deceleration time to
decelerate from the maximum
output frequency to 0 Hz.
Yes Q Q Q Q 2 01H 6-20
Decel Time 1
C1-03
Acceleration time 2
Sets the acceleration time when
the multi-function input “accel/
decel time 1” is set to ON.
Yes A A A A 2 02H 6-20
Accel Time 2
C1-04
Deceleration time 2
Sets the deceleration time when
the multi-function input “accel/
decel time 1” is set to ON.
Yes A A A A 2 03H 6-20
Decel Time 2
C1-05
Acceleration time 3
Sets the acceleration time when
the multi-function input “accel/
decel time 2” is set to ON.
Yes A A A A 2 04H 6-20
Accel Time 3
C1-06
Deceleration time 3
Sets the deceleration time when
the multi-function input “accel/
decel time 2” is set to ON.
No A A A A 205H 6-20
Decel Time 3
C1-07
Acceleration time 4
Sets the acceleration time when
the frequency reference is
below the value set in C1-11.
No A A A A 206H 6-20
Accel Time 4
C1-08
Deceleration time 4
Sets the deceleration time when
the frequency reference is
below the value set in C1-11.
No A A A A 207H 6-20
Decel Time 4
C1-09
Emergency stop
time
Sets the deceleration time when
the frequency reference is
below the value set in C1-11.
No A A A A 208H 6-10
Fast Stop Time
C1-10
Accel/decel time
setting unit
Sets the number of decimals for
the acceleration / deceleration
time parameters.
0:0.01-second units
1:0.1-second units
0 or 1 0 No A A A A 209H -
Acc/Dec Units
C1-11
Decel time switch-
ing frequency
Sets the frequency for automatic
acceleration/deceleration
switching.
If the output frequency is below
the set frequency: Accel/decel
time 4
If the output frequency is above
the set frequency: Accel/decel
time 1.
0.0 to
120.0
0.0 Hz No A A A -
20AH
6-20
6-21
Acc/Dec SW Freq
0.0 to
100.0
0.0 % No - - - A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron VARISPEED L7 and is the answer not in the manual?

Omron VARISPEED L7 Specifications

General IconGeneral
BrandOmron
ModelVARISPEED L7
CategoryInverter
LanguageEnglish

Related product manuals