3-6
3
Switching Modes
The mode selection display appears when the MENU key is pressed. Press the MENU key from the mode
selection display to switch through the modes in sequence.
Press the DATA/ENTER key to enter a mode and to switch from a monitor display to the setting display.
Fig 3.4 Mode Transitions
INFO
To run the inverter after viewing/changing parameters press the MENU key and the DATA/ENTER key in
sequence to enter the Drive mode. A Run command is not accepted as long as the drive is in any other
mode.
To enable Run commands from the terminals during programming set parameter b1-08 to “1”.
Frequency Ref
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
** Main Menu **
-DRIVE-
Operation
** Main Menu **
-QUICK-
Quick Setting
** Main Menu **
-ADV-
Programming
** Main Menu **
-VERIFY-
Modified Consts
** Main Menu **
-A.TUNE-
Auto-Tuning
Rdy
U1- 01=50.00Hz
Monitor
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
Rdy
U1 - 01=50.00Hz
Control Method
-QUICK-
A1-02 = 0
Initialization
-ADV-
A1 - 00=0
Select Language
None Modified
-VERIFY-
Frequency Ref
-DRIVE-
U1-02=50.00Hz
U1-03=10.05A
U1- 01=50.00Hz
Select Language
-ADV-
English
The constant number will be displayed if a
constant has been changed. Press the
DATA/ENTER key to enable the change.
Monitor Display
Setting Display
Mode Selection
Display
Display During Run
V/f Control
Tuning Mode Sel
-A.TUNE-
Standard Tuning
"0"
Tuning Mode Sel
-A.TUNE-
Standard Tuning
"0"
Rdy
T1- 01
= 0
*0*
T1- 01= 0
*0*
*0*
MENU
MENU
MENU
MENU
MENU
RESET
RESET
ESC
ESC ESC
ESC ESC ESC
ESC
ESC ESC
"0"
Control Method
-QUICK-
A1-02 = 0
V/f Control
*0*
"0"
A1-00 = 0
*0*
"0"
Select Language
-ADV-
English
A1-00 = 0
*0*
"0"