10.36
ELECTRICAL
9924096 - 2013 RANGER RZR XP 900 / RZR XP 4 900 Service Manual
© Copyright 2012 Polaris Sales Inc.
Starter Solenoid Bench Test
Test the start solenoid by powering the solenoid using
battery voltage for a
maximum of 5 seconds. With the
solenoid energized, resistance should read about 0 - 0.5
ohms between terminals (A) and (B). If resistance
measurement is out of specification, replace the starter
solenoid.
Starter Solenoid Operation
To energize the Starter Solenoid the following must occur:
• The brake must be applied to provide a ground
path via the Orange wire.
• The key switch must be turned to the “start”
position to provide 12V power via the Green /
White wire.
• Once the pull-in coil is energized, the solenoid
provides a current path for 12V power to reach the
starter motor.
NOTE: See “ELECTRICAL SYSTEM BREAOUTS:
Starter-Interlock” provided in this chapter for starter
solenoid operation.