Chapter 15: Maintaining Your Library
Maintaining Air Filters
686 Quantum Scalar i6000 User’s Guide
Replacing an Air Filter Use these instructions to replace either a top or bottom air filter.
Note: Make sure that the air filter is completely dry before placing it
back in the access door.
Required tools: #1 Phillips screwdriver
FRU ID: 1001 (air filter)
1 Take the library offline.
For information about taking the library offline, see Changing the
Library’s State on page 475.
2 On the operator panel, press Robotics Enabled to turn off power to
the picker and return it to the home position. The power is on to all
other components.
3 Open the access door. Aisle power is disabled.
4 Place the filter in the opening.
5 Place the retaining bar over the filter to hold it in place. Use the
Phillips screwdriver to tighten the two retaining thumbscrews.
6 Close the access door.
thumbscrew
retaining bar
thumbscrew