Service Mode Table
G133 5-234 SM
5930 010 PCU *EGB
Displays or does not display the end
display for the PCU. This SP is activated
only when the SP5930-001 is set to "1".
[0 or 1 / 1 / -]
0: OFF, 1: ON
5930 014 Mid Trans Unit *EGB
Displays or does not display the end
display for the image transfer belt unit.
This SP is activated only when the
SP5930-001 is set to "1".
[0 or 1 / 1 / -]
0: OFF, 1: ON
5930 016 Fusing Unit. *EGB
Displays or does not display the end
display for the fusing unit. This SP is
activated only when the SP5930-001 is set
to "1".
[0 or 1 / 1 / -]
0: OFF, 1: ON
5987 [Counter Falsification Prevention]
001 0: OFF / 1: ON
This SP detects that a mechanical counter device is
removed. If it is detected, SC610 occurs.
The mechanical counter is provided only for
NA model.
5988 [Contract Type]
Maintenance ID Setting *CTL
[1 or 2 / 1 / 1/step]
1: Yearly contract, 2: Meter Click
001
Selects the contract type.
5990 [SP print mode]