User Maintenance Items
SM 2-1 G133
Preventive
Maintenance
2. PREVENTIVE MAINTENANCE
2.1 USER MAINTENANCE ITEMS
The user replaces the following maintenance items.
2.1.1 MAINFRAME
Replacement Items
Item Remarks
PCU - BK, C, M, Y
Waste Toner Bottle
40 KP (YMC, BK)
Fusing Unit
Paper Transfer Roller
120 KP
Image Transfer Belt Unit
Dust Filter
160 KP
Chart: A4 (LT), 5%
Mode: 3 pages/Job
Environment: Recommended temperature and humidity
Yield changes depend on circumstances and print conditions
An error message shows when a maintenance counter gets to the value in the PM table
when the machine’s default settings are used.
It is not necessary to reset counters for each part. The machine detects new components
automatically and resets the necessary counters.