Service Mode Table
SM 5-33 G133
Service
Tables
position of the ferrite roller. After the ferrite roller rotates more than 40 times,
the machine starts to find the home position of the ferrite roller.
Continuous Feed Page *ENG
[100 to 1000 / 500 / 10 sheets/step]
002
Specifies the limit sheets of outputs for initializing the home position of the
ferrite roller. When the outputs are more than 500 sheets of paper, the machine
starts to find the home position of the ferrite roller.
SP2-XXX (Drum)
2005
[Charge DC Voltage] Charge Roller DC Voltage Adjustment
(Paper Type, Process Speed, Color)
Paper Type –> Plain, Thick 1, Thick 2
Adjusts the DC component of the charge roller bias in the various print modes.
Charge bias (DC component) is automatically adjusted during process control;
therefore, adjusting these settings does not effect while process control mode
(SP3-041-1 Default: ON) is activated. When deactivating process control mode
with SP3-041-1, the values in these SP modes are used for printing.
001 Plain: Bk *ENG
002 Plain: M *ENG
003 Plain: C *ENG
004 Plain: Y *ENG
005 Thick 1: Bk *ENG
006 Thick 1: M *ENG
007 Thick 1: C *ENG
008 Thick 1: Y *ENG
009 Thick 2&FINE: Bk *ENG
010 Thick 2&FINE: M *ENG
[0 to 1000 / 690 / 10 –volts/step]