Development
SM 6-25 G179
Detailed
Descriptions
paper trays. Thicker paper, OHP sheets, etc. can also be loaded in the by-pass tray but
adjustments must be performed with the SP modes listed below in order to avoid jams and
misfeeds.
SP Mode SP Name
SP2201 1 Development Bias Width 216 - 297 mm (Default: -560V)
SP2914 3
Process Control Setting (Bγ)
Adjust 10V/step (Default: 200V)
SP2914 4
Process Control Setting (Bδ)
Adjust 10V/step (Default: 50V)
The way that these SP modes are used is shown below.
For example, with the default settings, if the paper width fed from the by-pass tray is 200
mm, the development bias voltage will be –560 + 50 V.