CQ
21
Streaks
(TYPE
2.2,
Deleted Streaks)
(Continued)
Probable
Cause
4.
Damaged media or damp media.
Corrective Action
4b.
Roll media
Remove and discard the first
3
to
6
feet
(1
to
2
metres) of media from the roll. Make a copy on
the new media.
If the problem
is
corrected, ensure that the roll
media
is
being stored correctly.
5.
Contaminants in the developer material.
5.
Inspect the developer material for foreign
material and replace the developer material (REP
9.8)
if
necessary. Perform the Electrostatic Series
(2510
ADJ
9.2;
2515 ADJ
9.3).
6.
Developer housing
is
not seated correctly.
6.
Ensure that the developer housing
is
seated
correctly. Ensure that
the
developer housing
is
operating
correctly.
7.
Contaminated or damaged photoroceptor drum,
7.
W~sh (General Procedures) or replace tho
photoreceptor drum (REP 9.3) as required.
Perform the Electrostatic Series (2510 ADJ 9.2;
251
5
ADJ
9.3).
8.
(25
10
ONLY):
The developer seal
is
damaged.
8.
(2510
ONLY):
Replace the developer seal
CAUTION
Developer Module Repair Kit (PL 9.4).
Only the
2510
developer module can be repaired
using the developer module repair kit. The
2515
developer module is the same as the
2520
and
cannot be repaired, The manufacturing tolerances
are much tighter and cannot be set with out the
correct tools
9.
The auger to drum seal
is
damaged.
9.
Replace the auger to drum seal
(PL
9.1).
11
0. Damaged latch springs.
10.
Replace the Latch Springs (PL
9.2).
8196
,
4
3-87
CQ
21
Streaks
(Type
2.2,
Deleted
Streaks)