ADJ
3.3
Timeout
Interval
to
Power
Saver
Mode
(251
5)
Purpose
The purpose
is
to set the amount of time
it
takes
the copier to return to the standby mode from
the run mode.
Introduction
The timeout interval should be set to the
requirements of the customer. The time
is
preset by manufacturing for 1 minute. The time
interval can be set from
45 seconds to
3
minutes.
Adjust
1.
Enter the diagnostic mode.
2.
Select test
1.
Press Start.
3. Use the
Copy
Contrast LlghterlDarker
buttons to increaseldecrease the value
displayed on the control panel.
NOTE:
Increasing the value displayed will
increase the run time interval after the
last copy was made. One number will
increase or decrease the interval by
15
seconds,
4.
Press the Start button to enter and store the
new setting.
5.
Exit
the
diagnostic
mode.
AD1
3.4
Foreign Accessory
Enablement
Purpose
The purpose
is
to select or deselect the foreign
interface feature and determine the interaction
of the foreign interface output pulse.
Adjust
1.
Enter
the
diagnostic mode.
2.
Enter code 1 (2510 WlTag
26)
or enter code
2 (25 15). Press Start.
3.
Enter
the
cleisred vnlue.
1
Function
1
value
The foreign interface
is
enabled and
an output pulse
is
generated at the
completion of each copy.
5.
Exit
the diagnostic mode.
The foreign interfce
is
not enabled.
The foreign interface
is
enabled and
an output pulse
is
generated each
time the copy count meter registers
on
increment.
7/92
25101251 5
4-57
ADJ
3.3,
ADJ
3.3,
2
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox 2510 and is the answer not in the manual?

Xerox 2510 Specifications

General IconGeneral
BrandXerox
Model2510
CategoryCopier
LanguageEnglish

Related product manuals