CQ
27
Exposure
RAP
This RAP
is
used if there
is
no exposure or an
excessive amount of exposure. No exposure
will give a black copy and an excessive
amount of exposure will give a washed out
COPY
-
I
Ensure that connectors
PI
1 of the Control
PWB
and
P21
and
P2Z
of the lamp ballast are
connected correctly. Ensure that the
exposure lamp sockets ore not damaged and
the lamp
is
fully in the lamp sockets. Ensure
that the clear slot
is
facing the Illumination
Sensor
NOTE:
Do not leave the exposure lamp on
for an extended amount of time.
The photorecptor drum could be
damaged by the
light
shock.
Enter the code
F.
The exposure lamp lights.
The lamp filaments are on.
Y
N
There
is
-1-0.7
VDC
between pins
4
(+)
and
3
(0)
of
PI1
on the Control
PWB,
Y
N
Go to FLAG
1
and check the
wiring between the Control
PWB
and the lamp ballast for an open
circuit.
If there
is
no open circuit, replace
the Control
PWB.
Replace the lamp ballast.
There is
+
24
VDC between pins
6
(
+
)
and
3
(-)of
PI 1
on the Control
PWB.
Y
N
Go to FLAG
2
and check the wiring
between the Control
PWB
and the
lamp ballast for an open circuit.
If there
is
no open circuit, replace the
lamp ballast.
Press Stop then Start. The voltage
between pins
6
(+)
and
3
(-)
of
PI1
on
the Control
PWB
goes from
+
24
VDC to
+
0.6
VDC.
(
Replace the Control
PWB.
Replace the lamp bnllnst
If the problem
still
exists, replace the
exposure lamp.
connect the multimeter to
P11-7
(
+
)
on the
lamp ballast
PWB.
Connect the
(-)
to ground.
CAUTION
(2510,2515
WIO
Tag
2,
7,
or
89):
To prevent
damage to the drive gears; before entering
any diagnostic test which requires the use of
the main drive motor [A]; always enter the
codes [L] cleaning blade solenoid, [g] fuser
and
[J]
cooling fans first, and then allow the
copier to operate for at least
2
minutes.
Then press code
[A]
to start the main drive
motor.
WARNING
(2515
W/
Tags
2,7,
or
89):
There will
be
a
time delay between the time the code
[A]
is
entered and the time the motor starts to
turn. The motor will not start
until
the
fuser is at the correct temperature.
(251 0,251 5
W/O
Tag
2
or
89):
Enter the diagnostic mode.
0
enter code
[L]
and press Start.
enler code [g)
and
press Start.
enter code
IJI
and press Start.
0
wait
at
least
2
minutes.
0
enter code [A] and press Start.
enter code
[5]
and press Start.
Record the existing NVM value. Observe
the meter indication. Observe the
multimeler. Scroll to
a
value of
9,
press
Start, continue scrolling past
9
to a value of
1
press Start.
(2515
W/
Tag
2,7,
or
89):
Enter the diagnostic mode.
enter code
[5]
and press
Start.
Record the existing NVM value. Observe
the meter indication. Observe the
multimeter. Scroll to a value of
9,
press
Start, continue scralling past
9
to a value of
1
press Start.
-
-
-
-
-
-
-
CQ
27
Exposure
RAP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox 2510 and is the answer not in the manual?