Checking the Display Status
If the Digital Operator's display at the time the power is connected is normal, it will read as follows:
When an fault has occurred, the details of the fault will be displayed instead of the above display. In that case,
refer to Chapter 7 Troubleshooting. The following display is an example of a display for faulty operation.
Setting the Control Method
Any of the following five control methods can be set.
Note With vector control, the motor and Inverter must be connected 1:1. The motor capacity for which stable control is possible is 50% to 100% of the capac-
ity of the Inverter.
Display for normal operation
The frequency reference monitor is dis-
played in the data display section.
Display for fault operation
The display will differ depending on the
type of fault.
A low voltage alarm is shown at left.
Control Method
Constant
Setting
Basic Control Main Applications
V/f control A1-02 = 0 Voltage/frequency ratio fixed control
Variable speed control, particularly
control of multiple motors with one
Inverter and replacing existing Invert-
ers
V/f control with PG A1-02 = 1
Voltage/frequency ratio fixed control
with speed compensation using a PG
Applications requiring high-precision
speed control using a PG on the
machine side
Open-loop vector 1
control
A1-02 = 2
(factory setting)
Current vector control without a PG
Variable speed control, applications
requiring speed and torque accuracy
using vector control without a PG
Flux vector control A1-02 = 3 Flux vector control
Very high-performance control with a
PG (simple servo drives, high-preci-
sion speed control, torque control, and
torque limiting)
Open-loop vector 2
control
A1-02 = 4
Current vector control without a PG
with an ASR (speed controller)
(Always perform rotational autotun-
ing.)
Very high-performance control with-
out a PG (torque control without a PG,
torque limiting, applications requiring
a 1:200 speed control range without a
PG)
-DRIVE-
Frequency Ref
U1-01= 0 0 0.0 0Hz
-DRIVE-
Rdy
Frequency Ref
U1- 01= 60.0 0Hz
U1-03=10.05A
U1-02=60.00Hz
01
01
Frequency Ref
-DRIVE-
UV
DC Bus Undervolt
TOE-S616-60.1.book 4 ージ 2017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals