-18
Acceleration and Deceleration Characteristics
This section explains the acceleration and deceleration characteristics of the Inverter.
Setting Acceleration and Deceleration Times
Acceleration time indicates the time taken for the output frequency to climb from 0% to 100%. Deceleration
time indicates the time taken for the output frequency to reduce to 0%. The factory setting of the acceleration
time is C1-01, and the factory setting of the deceleration time is C1-02.
Related Parameters
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
C1-01
Acceleration
time 1
Sets the acceleration time to accel-
erate from 0 to the maximum output
frequency, in 1-second units.
0.0 to
6000.0
*
10.0 s
YesQQQQQ200H
Accel Time 1
C1-02
Deceleration
time 1
Sets the deceleration time to decel-
erate from the maximum output fre-
quency to 0, in 1-second units.
YesQQQQQ201H
Decel Time 1
C1-03
Acceleration
time 2
The acceleration time when the
multi-function input “accel/decel
time 1” is set to ON.
YesAAAAA202H
Accel Time 2
C1-04
Deceleration
time 2
The deceleration time when the
multi-function input “accel/decel
time 1” is set to ON.
YesAAAAA203H
Decel Time 2
C1-05
Acceleration
time 3
The acceleration time when the
multi-function input “accel/decel
time 2” is set to ON.
NoAAAAA204H
Accel Time 3
C1-06
Deceleration
time 3
The deceleration time when the
multi-function input “accel/decel
time 2” is set to ON.
NoAAAAA205H
Decel Time 3
C1-07
Acceleration
time 4
The acceleration time when the
multi-function input “accel/decel
time 1” and “accel/decel time 2” are
set to ON.
NoAAAAA206H
Accel Time 4
C1-08
Deceleration
time 4
The deceleration time when the
multi-function input “accel/decel
time 1” and “accel/decel time 2” are
set to ON.
NoAAAAA207H
Decel Time 4
C1-10
Accel/decel
time setting
unit
0: 0.01-second units
1: 0.1-second units
0 or 1 1 No A A A A A 209H
Acc/Dec
Units
TOE-S616-60.1.book 18 ージ 017年8月4日 金曜日 午後3時41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed G7 Series and is the answer not in the manual?

YASKAWA Varispeed G7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed G7 Series
CategoryInverter
LanguageEnglish

Related product manuals