6.14.9 Built-in alarms
ANSI CODE
PROTECTION (ALARM)
Emergency stop
12
Engine overspeed
14
Engine underspeed
Start Fail
RPM measurement failure
Stop Fail
GCB Fail
MCB Fail
Forward synchronization timeout
Reverse synchronization timeout
32
Generator overload
32R
Generator reverse power
59, 27
Generator under/overvoltage
47
Generator voltage unbalance
81H, 81L
Generator under/overfrequency
51
Generator overcurrent
50
Generator short current
46
Generator current unbalance
47
Phase sequence
Maintenance timer
Charging alternator fail
Battery voltage
Governor output at limit
AVR output at limit
Battery flat
Low backup battery
6.15 History log
The history log is an area in the controller’s non-volatile memory that recordssnapshotsof the
system at moments when important events occur. The history log is important especially for
diagnostics of failures and problems. Its capacity is over 100 records and it works as FIFO, i.e. the
newest record overwrites the oldest one.
Each record has the same structure and contains:
The event which caused the record (e.g. Overspeed alarmor GCB closed”)
The date and time when it was recorded
All important data values like RPM, kW, voltages, etc. from the moment that the event
occurred.
BASIC VALUES

Table of Contents

Other manuals for ComAp InteliCompact NT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliCompact NT and is the answer not in the manual?

ComAp InteliCompact NT Specifications

General IconGeneral
BrandComAp
ModelInteliCompact NT
CategoryController
LanguageEnglish

Related product manuals