EasyManuals Logo
Home>Dell>Server>E28S Series

Dell E28S Series User Manual

Dell E28S Series
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Table 8 Diagnostic indicators (continued)
Icon Description Condition Corrective action
failed power supply unit
(PSU) or voltage
regulator).
Reseat the PSU. If the problem
persists, see the Getting help section.
Temperatur
e indicator
The indicator flashes
amber if the system
experiences a thermal
error (for example, the
ambient temperature is
out of range or fan
failure).
Ensure that none of the following
conditions exist:
l
A cooling fan has been removed or
has failed.
l
System cover, cooling shroud, EMI
filler panel, memory module blank,
or back filler bracket is removed.
l
Ambient temperature is too high.
l
External airflow is obstructed.
See the Getting help section.
Memory
indicator
The indicator flashes
amber if a memory error
occurs.
Check the system event log or system
messages for the location of the failed
memory. Reseat the memory module.
If the problem persists, see the Getting
help section.
Hard drive indicator codes
Each hard drive carrier has an activity indicator and a status indicator. The indicators provide
information about the current status of the hard drive. The activity LED indicates whether hard
drive is currently in use or not. The status LED indicates the power condition of the hard drive.
Figure 9
Hard drive indicators
1. hard drive activity indicator
2. hard drive status indicator
Dell PowerEdge R430 system overview
Dell PowerEdge R430 Owner's Manual 27

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell E28S Series and is the answer not in the manual?

Dell E28S Series Specifications

General IconGeneral
BrandDell
ModelE28S Series
CategoryServer
LanguageEnglish

Related product manuals