Figure 75 Reconfiguring the portable lift with the Voyager conversion kit
CL5422
1 2
Adjusting the arms for a frontal lift
If you plan to use the mechanical lift directly in front of the cabinet, adjust the lift
arm/tray width to just under 17 inches apart to ensure that the arms will stay under
the chassis. Figure 76 on page 102 shows an example of adjusting the lift arm/tray to
just under 17 inches.
Procedure
1. Add the two arms with rollers 17 inches apart measured from the outside edge
of each arm.
2. Tighten the arms to secure them.