Installing the front bezel
Procedure
1. Align the bezel with the shelf.
2. Gently push the bezel into place on the cabinet until it latches.
3. If the bezel has a key lock, lock the bezel the provided key.
Complete the procedure
Procedure
1. Return the failed or replaced part(s) to EMC Data Domain. Reuse the packaging
from the new part(s) and use the included prepaid waybill for shipping.
Reference the RMA number on the outside of the package.
2. Send an autosupport report from the system by entering the autosupport
send command.
Chassis removal
This section describes how to remove a fully populated chassis for the purposes of
transferring FRUs to a replacement chassis. Since a fully populated chassis weighs
approximately 225 pounds, the following are required to remove and replace a chassis:
l
A lift that can support the shelf for both removing and transferring FRUs;
l
A work surface capable of holding two shelves, side-by-side;
l
An interim table capable of supporting a fully populated shelf.
These are needed to do the following:
l
If required, reconfigure the lift so it can be moved to its lowest setting to transport
the shelf. this will have to be done if the shelf was removed from a location that
was 49" or higher from the floor;
l
Remove the shelf from the rack;
l
Move the shelf to an interim table;
l
Place the shelf back on the lift, lower it as far as possible, then transport it to the
work location;
l
Place the shelf side-by-side with the replacement chassis, then the FRUs are
transferred.
Note
When removing the disk drives, each disk drive must be transferred into the
corresponding location in the replacement chassis..
Working with the portable lift
If a shelf with all of the FRUs removed is being installed, the chassis can be installed
without using the lift. If the shelf is populated with FRUs prior to installing, then this
task requires the use of a portable lift.
The portable lift commonly used by EMC service personnel is manufactured by Alum-
A-Lift. Instructions for this lift are included in the lift kit. Refer to "http://
Removing and Replacing FRUs
Installing the front bezel 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Data Domain DS60 and is the answer not in the manual?

EMC Data Domain DS60 Specifications

General IconGeneral
BrandEMC
ModelData Domain DS60
CategoryServer
LanguageEnglish

Related product manuals