Adjusting the arms for a frontal lift
If you plan to use the mechanical lift directly in front of the cabinet, adjust the lift
arm/tray width to just under 17 inches apart to ensure that the arms will stay under
the chassis. Figure 5 on page 27 shows an example of adjusting the lift arm/tray to
just under 17 inches.
Procedure
1. Add the two arms with rollers 17 inches apart measured from the outside edge
of each arm.
2. Tighten the arms to secure them.
Figure 5 Adjusting the lift arm bar to just under 17 inches
Installing the shelf onto the rails
Before you begin
If a shelf with all of the FRUs removed is being installed, the chassis can be installed
without using the lift. If the shelf is populated with FRUs prior to installing, then this
task requires the use of a portable lift.