13.2 General Specifications
166
Basic Specifications
Backup lithium battery life Clock and settings (Lithium battery), Approx. 10 years @23°C (@73.4°F)
Real-Time Clock function Auto-calendar, leap-year correcting 24-hour clock
Real-time clock accuracy ±0.3 s per day (instrument on, 23°C±5°C (73°F±9°F)
±1 s per day (instrument on, within operating temperature and humidity range)
±3 s per day (instrument off, @23°C (@73.4°F))
Memory data capacity SD memory card/ SDHC memory card 2G to 32GB
Maximum recording period 55 weeks (with repeated recording settings of [1 Week], 55 iterations)
55 days (with repeated recording settings of [1 Day], 55 iterations)
35 days (with repeated recording settings of [OFF])
Maximum recordable events 55000 events (with repeated recording on)
1000 events (with repeated recording off)
Power supply Z1002 AC Adapter (12 VDC)
Rated supply voltage : 100 VAC to 240 VAC (Voltage fluctuations of
10% from the rated
supply voltage are taken into account.)
Rated power supply frequency : 50/60 Hz, maximum rated current:1.7 A, anticipated transient
overvoltage 2500 V
Anticipated transient overvoltage: 2500 V
Z1003 Battery Pack (Ni-MH 7.2VDC 4500 mAh)
Recharge function The battery pack charges regardless of whether the instrument is on or off.
Charge time: Max. 5 hr. 30 min. @23°C (@73.4°F)
Charging temperature range: 10°C to 35°C (50°F to 95°F)
Maximum rated power 35 VA (when charging)
15 VA (when not charging)
Continuous battery operation time Approx. 180 min. (@23°C (@73.4°F), when using Z1003 Battery Pack)
Dimensions Approx. 300 W× 211 H × 68 D mm (11.81" W × 8.31" H × 2.68" D) (excluding protrusions)
Mass Approx. 2.2 kg (77.6 oz.) (excluding battery pack)
Mass of battery pack: Approx. 365 g (12.9 oz.)
Power supply quality
measurement method
IEEE1159, IEC61000-4-30Ed2:2008
Display specifications
Display 6.5-inch TFT color LCD (640×480 dots)
Display defects: 5 or fewer dead pixels, 1 or fewer bright pixels
External Interface Specifications
(1) SD card Interface
Slot SD standard compliant × 1
Compatible card SD memory card/ SDHC memory card (Use only HIOKI-approved SD memory cards)
Supported memory capacity SD memory card: Up to 2GB, SDHC memory card: Up to 32GB
Functions Saving of binary data (settings data) (up to 9,999 files)
Up to 100 files of measurement data can be saved on the same date.
Saving of settings files (up to 102 files)
Loading of settings files (up to 102 files)
Saving of screen copies (up to 99,999,999 files)
Loading of screen copies
Formatting of SD memory cards
Deleting of files
Media full processing Saving of data to SD memory card is stopped (time series data is stored on a first-in, first-out basis.)
(2) RS-232C Interface
Connector D-sub9 pin ×1
Method RS-232C “EIA RS-232D”, “CCITT V.24”, “JIS XS101” compliant
Connection destination Printer, GPS box (cannot be connected to computer)
Functions Printer : Printing of screen copies
GPS : Measurement and control using GPS-synchronized time
(3) LAN Interface
Connector RJ-45 × 1
Electrical specifications IEEE 802.3-compliant Ethernet
Transmission method 10BASE-T/ 100BASE-TX
Protocol TCP/IP

Table of Contents

Other manuals for Hioki PW3198

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hioki PW3198 and is the answer not in the manual?

Hioki PW3198 Specifications

General IconGeneral
BrandHioki
ModelPW3198
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals