CNI2
O
perating and Installation
Guide
105
CODE
DESCRIPTION
21
The
CNI2
cannot make a connection in CSD mode. This could be caused if
the s
ervice provider does not support CSD connections or if the modem that
is being called is not connecting.
22
The GSM SIM card is defective or cannot be read. Try another SIM card. A
SIM card is a memory device and can be damaged by static discharge. If
another SIM card also fails then this indicates an electrical problem with the
radio or the
CNI2
board.
23
The radio does not respond properly to an echo
-
off command. This is a
problem with the radio.
24
The radio cannot be initialized. This can be caus
ed by a nearly depleted
battery. Otherwise the radio or GSM SIM card may be defective.
25
The radio did not return a proper response to a command. This is a problem
with the radio or perhaps the GSM SIM card.
26
Packet (Internet) service is not avail
able. This is a problem with the network
or with the way the cellular account has been set up.
27
The radio does not respond properly to an SMS command. This is a
problem with the radio.
28
The over
-
the
-
air
-
activation (OTAA) call failed (CDMA units onl
y)
29
Not used
30
Logic supply Vcc is less than 2.8V during light
-
load conditions. This is
generally caused by a nearly depleted battery.
31
Logic supply Vcc is less than 2.8V during heavy
-
load conditions (radio
powered up). This is generally caused b
y a nearly depleted battery or a
power source that cannot supply the current required by the radio.
32
The output of the radio’s regulator circuit is less than 3.4V.
33
There is a data retention problem with the non
-
volatile EEPROM memory
device.
34
The
board has not been calibrated.
35
Problem reading voltages and temperature (A/D converter problem)
36
Not used
37
Not used
38
There is no primary phone number to dial or no primary IP address to
connect to. Check the configuration.
39
There is a co
mmunications problem with the non
-
volatile EEPROM memory
device.
LED Error Codes 21 thru 39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell CNI2 and is the answer not in the manual?

Honeywell CNI2 Specifications

General IconGeneral
BrandHoneywell
ModelCNI2
CategoryRecording Equipment
LanguageEnglish

Related product manuals