Operation - System Configuration
Fusion4 MSC-L Part No.: 4418309_Rev09
5 - 124 Installation & Operation Manual
Honeywell
The System Config . Alarms . Deadman screen appears. The
deadman function of the MSC-L allows the loading process to be
monitored to ensure the operator's attention and safety during the
loading operation.
2. On the System Config . Alarms . Deadman screen, the following
entities are displayed.
5.13.1.5.3.1 Deadman Status
5.13.1.5.3.2 Deadman Indicator
5.13.1.5.3.3 Deadman bell
Entity Description Value range
[Deadman status]
With this entity you can <Enable> or
<Disable> deadman alarm function.
If enabled, the operator/driver must
repeatedly (within the settable timeout
period) press a key on the keyboard of
the MSC-L or press deadman refresh
switch to prevent the deadman function
from being triggered.
<Enable>
<Disable> (default)
Entity Description Value range
[Output] With this entity you can select the
physical output for the deadman
indicator function.
Any of the unused DO-SSR, DO-EMR, PO,
or None.
The default value is
<None>.
[Timeout]
With this entity you can set the time in
seconds in which the operator must
press a key or refresh the deadman
switch in an interval of
[Deadman
indicator timeout]
to prevent the
deadman indicator (warning) lamp from
being activated and deadman bell
(siren) start the beep.
<10> s ... <999> s
(default = <150> s)
Entity Description Value range
[Output] With this entity you can select the
physical output for the deadman bell
function.
Any of the unused DO-SSR, DO-EMR, PO,
or None.
The default value is
<None>.
[Timeout]
With this entity you can set the time in
seconds in which after the deadman
indicator output activates, the operator
must press a key or deadman switch
refresh to prevent the batch from being
paused and deadman bell activate
continuously.
<10> s ... <999> s
(default = <30> s)