Operation - Stream Configuration
Fusion4 MSC-L Part No.: 4418309_Rev09
5 - 162 Installation & Operation Manual
Honeywell
5.14.1.4.3 Stream Config. Stream n . Volume Conversion
On the Stream Config . Stream n screen, select <Volume conversion>.
The Stream Config . Stream n . Volume Conversion screen appears
with the following entities.
5.14.1.4.3.1 Conversion Options
On the Stream Config . Stream n . Volume Conversion screen, select
<Conversion options>.
The Stream Config. Stream n . Conversion Options screen is
displayed with the following entities.
Entity Description Value range
[Commodity group]
With this entity you can select the
commodity group of the product in
compliance with the specific applicable
standard.
<None>
<D1250-04 (Crude oil)>
<D1250-04 (Refined Prod.)>
(default)
<D1250-04 (Special Apps.)>
<D1250-04 (Lub. Oils)>
<TP27-07 (NGL & LPG)>
<EN14214-08 (FAME)>
<CNP6-70> (Petroleum)
<NBR15639-08> (Ethanol Mix)
<MPMS 11.3.3> (Pure Ethanol)
<MPMS 11.3.3> (Fuel Ethanol)
<D4311-15> (dsp halt
)
[Compensation used]
With this entity you can select the type
of compensation used during the
calculation of GSV and mass (pressure
compensation is not applicable for the
FAME commodity group).
<None> (default)
<Temperature>
<Temperature & pressure>
[Density input used]
With this entity you can select whether
the density sensor input at metering
conditions is used for volume
conversion calculations (instead of
laboratory observed density value).
<False> (default)
<True>
[Range options]
With this entity you can select the
options enabled when using the VCF
table.
The extended temperature, pressure
and range give the ability to
do the volume conversion over a
broader range than covered by the
earlier versions of the standard. For
instance at locations where it is very
cold, like Alaska.
When
<None> is selected and the
application goes beyond the normal
range, an error occurs.
<None> (default)
<Extended range>