Alarm Handling - List of all alarms
Part No.: 4418309_Rev09 Fusion4 MSC-L
Honeywell Installation & Operation Manual 6 - 13
VCF no solution The No Solution error occurs during the volume correction
calculation used in the MSC-L.
VCF illegal argument The Illegal argument error occurs during the volume
correction calculation used in the MSC-L.
VCF pressure com-
pensation not sup-
ported
The Pressure Compensation not supported error occurs
during the volume correction calculation used in the MSC-L.
VCF bad sensor
health
The Bad sensor health error occurs during the volume
correction calculation used in the MSC-L.
Pulse hardware fault The pulse input module detects the following error
conditions.
• Reading information from the Pulse Input processor.
• Pulse overflow errors.
• BAD health of the pulse input function.
Pulse phase fault The dual pulse inputs are out of phase.
It is only possible if the MSC-L is configured for quad pulse.
Tank low level A Tank low level signal is received. This signal is received
only when the I/O binding input (DI, PI, and so on) are not
active for the Tank low level input.
Tank empty A Tank empty signal is received. This signal is received only
when the I/O binding input (DI, PI, and so on) are not active
for the Tank empty input.
Temperature sensor
fault
Temperature sensor fault is detected on the temperature
sensor on the product stream.
Low temperature The instantaneous temperature is less than the configured
limits.
High temperature The instantaneous temperature is greater than the
configured limits.
Pressure sensor The pressure sensor fault is detected on the pressure
sensor on the product stream.
Low pressure The instantaneous pressure is less than the configured
limits.
High pressure The instantaneous pressure is greater than the configured
limits.
Density sensor fault The density sensor fault is detected on the density sensor
on the product stream.
Low density The instantaneous density is less than the configured limits.
High density The instantaneous density is greater than the configured
limits.
Flowrate exceeded
meter limit
The flow rate exceeds the configured meter limits.
VCF invalid reference
condition
Invalid reference condition error occurs during the volume
correction calculation used in the MSC-L
Alarm Cause