Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
3102 I/O processor card detected interface error
Error occurred on SCSI bus 2.
Perform “SDIOP-PIP13” on page 404.
STORIOA
FI01107
FI01140
BACKPLN
3109 I/O processor timed out a device command
Perform “SDIOP-PIP16” on page 407.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
3110 I/O processor card detected interface error
Perform “SDIOP-PIP16” on page 407.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
3136 The removable media device is assigned elsewhere USER
FI01105
3200 A tape/CD or disk device reported a failure FI01105
STORIOA
IOP
MEDIA
3203 Disk media format bad FI01105
3205, 3215 Disk sector read error
Disk unit data may need to be reloaded, but the disk unit does not need to
be replaced.
FI01105
3250 Disk unit requires initialization before use.
Perform a D-IPL and work on errors found in the log.
USER
3300 Storage unit detected a media problem
Perform “SDIOP-PIP1” on page 401.
MEDIA
FI00121
FI01141
3400 I/O processor card detected device error
NOTE: If external devices are attached check EXTSCSI and DEVTERM first.
FI02112
STORIOA
FI01106
DEVTERM
FI01140
3401 Device backplane problem DEVBPLN
3501 I/O processor Licensed Internal Code error AJDGP01
IOP
3600 to 3601 System log entry only, no service action required
6070 A permanent I/O processor failure occurred IOP
6071 I/O processor Licensed Internal Code error AJDGP01
6072 I/O processor Licensed Internal Code error AJDGP01
IOP
6073 IPL device not ready MEDIA
FI01105
USER
6075 I/O processor resource not available AJDGP01
2749, 2767, 2768, 2842, 2843, 284B
126
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1