Does the same SRC occur ?
Yes No
If the system IPLs past the original error, then isolate to the failing IOP
or IOA card.
Follow the service actions for the new SRC.
5. Remove (and label) all of the storage device units EXCEPT for the alternate IPL
load-source device unit that you are currently using (This includes all of the
disk devices in D31-D40 and D46-D50.)
If the system IPLs past the original error, then isolate to the failing device unit.
If the failure still occurs, replace the following FRUs in order one at a time until
the problem is resolved. See Chapter 4. Removal and Installation Procedures
on page 617.
a. Load Source IOP in location C01 in the FC 9074 Base I/O Tower.
b. First storage IOA (location C02, C03 or C04) in the FC 9074 Base I/O Tower.
c. HSL I/O bridge Card in location C08 in the FC 9074 Base I/O Tower.
d. Network interface controller (NIC) card in location M06 in the 830 System
Unit.
e. Tower Card in location CB1 in the FC 9074 Base I/O Tower.
6. This is a Model 840, SB3 System Unit and FC 9079 Base I/O Tower.
See Table 42 on page 720.
Remove the IOPs and IOAs, EXCEPT for the load-source IOP and the first
storage IOA.
Does the same SRC occur ?
Yes No
If the system IPLs past the original error, then isolate to the failing IOP
or IOA card.
Follow the service actions for the new SRC
7. Remove (and label) all of the storage device units EXCEPT for the alternate IPL
load-source device unit that you are currently using. (This includes all of the
disk devices in D31-D40 and D46-D50.)
If the system IPLs past the original error, then isolate to the failing device unit.
If the failure still occurs, replace the following FRUs in order one at a time until
the problem is resolved. See Chapter 4. Removal and Installation Procedures
on page 617.
a. Load Source IOP in location C01 in the FC 9079 Base I/O Tower.
b. First storage IOA (location C02, C03 or C04) in the FC 9079 Base I/O Tower.
c. HSL I/O bridge Card in location C08 in the FC 9079 Base I/O Tower.
d. Network interface controller (NIC) card in location M17 in the 840 System
Unit.
e. Tower Card in location CB1 in the FC 9079 Base I/O Tower
This ends the procedure.
ALTMANL
An xSeries Server (formerly Netfinity) Service call may be needed to fix the
problem on the Integrated xSeries Server (IXS).
1. For SRC 1xxx-8910:
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 501