This ends the procedure.
7. Unplug the wrap plug from the Fibre Channel IOA and wait until the
2765/2766 3120 SRC occurs. This may take up to 10 minutes. The failure has
been isolated to the first link, which includes any of the cables, junctions, etc.
between the Fibre Channel IOA port and the first Fibre Channel hub, switch,
gateway or device. To continue diagnosis within this link, use existing Fibre
Channel service procedures or contact your next level of support.
This ends this procedure.
HSLCTLR
The failing item is the Network Interface Controller (NIC).
1. Is this system a Model 830/SB2 System Unit ?
Yes No
Go to Step 3 of this procedure.
2. Replace the following FRUs in order one at a time until the problem is
resolved.
Note: Be sure to IPL in SLOW OVERRIDE mode after each replacement.
a. Network interface controller (NIC) card in location M06 in the 830 System
Unit.
b. Clock card in location M06A in the 830 System Unit.
For location information see Locations Models 830, SB2 System Unit with
FC 9074 Base I/O Tower on page 709. To determine the correct remove and
replace procedure to use for the failing item, see Table 41 on page 710.
This ends the procedure.
3. This is a Model 840, SB3 System Unit and FC 9079 Base I/O Tower.
Replace the following FRUs in order one at a time until the problem is
resolved.
Note: Be sure to IPL in SLOW OVERRIDE mode after each replacement.
a. Network interface controller (NIC) card in location M17 in the 840 System
Unit.
b. Clock card in location M19 in the 840 System Unit.
For location information see Locations Models 840, SB3 System Unit with
Processor Tower and FC 9079 Base I/O Tower on page 719. To determine the
correct remove and replace procedure to use for the failing item, see Table 42 on
page 720.
This ends the procedure.
IDPART
A system unit part is failing. Perform the following:
1. Is the SRC 1xxx 8430, 8431, 8440, or 8441?
No Yes
Go to step 18 on page 543 of this procedure.
2. Is the SRC 1xxx 7405?
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 539