EasyManuals Logo
Home>IBM>Server>i 830

IBM i 830 User Manual

IBM i 830
1000 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #573 background imageLoading...
Page #573 background image
Yes No
Go to Step 4 of this procedure.
3. See Locations Models 830, SB2 System Unit with FC 9074 Base I/O Tower
on page 709.
Replace the following FRUs in order one at a time until the problem is
resolved. See Chapter 4. Removal and Installation Procedures on page 617.
Note: Be sure to IPL in SLOW OVERRIDE mode after each replacement.
a. Memory Riser Card in location M02 in the System Unit
b. Memory Riser Card in location M05 in the System Unit
4. This is a Model 840, SB3 System Unit and FC 9079 Base I/O Tower.
See Locations Models 840, SB3 System Unit with Processor Tower and FC
9079 Base I/O Tower on page 719. Replace the following FRUs in order one at
a time until the problem is resolved. See Chapter 4. Removal and Installation
Procedures on page 617.
Note: Be sure to IPL in SLOW OVERRIDE mode after each replacement.
a. Memory Cards in bank A in the System Unit
b. Memory Cards in bank B in the System Unit
c. Memory Cards in bank C in the System Unit
d. Memory Cards in bank D in the System Unit
This ends the procedure.
MUMIOCD
The failing item may be the Tower Card or the high-speed link (HSL) I/O adapter
card.
Perform the following:
1. Is the location from the Reference Code Table CB1?
Yes No
The HSL I/O bridge card may be the failing item.
Exchange the HSL I/O bridge card in location C08. To determine the
CCIN, part number and removal and installation procedure, locate card
position C08 and FRU name HSL I/O bridge card from the following:
v For Model 830, SB2 see Table 41 on page 710.
v For Model 840, SB3 see Table 43 on page 725.
This ends the procedure.
2. The failing item may be the Tower Card.
Exchange the Tower Card in position CB1. To determine CCIN, part number
and removal and installation procedure, locate card position CB1 and FRU
name Tower Card from the following:
v For Model 830, SB2 see Table 41 on page 710.
v For Model 840, SB3 see Table 43 on page 725.
This ends the procedure.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 559

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish