12. Is the SRC 2613?
No Yes
↓ Go to “Power Cord Part Numbers and Receptacle Descriptions” on
page 891.
13. Is the SRC 1xxx-8940, 8941, 8942 or 8943?
Yes No
↓ Go to “Starting Point for All Problems” on page 4.
14. Reseat the RS485 cable.
Does the same SRC appear?
Yes No
↓ Go to “Starting Point for All Problems” on page 4.
15. Exchange the RS485 cable asm part – 21P4162.
Does the same SRC appear?
Yes No
↓ Go to “Starting Point for All Problems” on page 4.
16. Go to the next FRU in the list.
This ends the procedure.
CCIN
Use the following table to identify the processor configuration for the system you
are working on. Then, continue with step one below.
Table 18. Processor Configuration Table
Model Processor
Feature Code
Processor
Capacity Card
CCIN
Interactive Card
CCIN
Proc 0
CCIN
Proc 1
CCIN
Proc 2
CCIN
Proc 3
CCIN
SB3 2318 2318 na 245F 245E 245E 245E
SB3 2316 1316 na 245F 245E
840 26D8 2461 1548 246F 246E 246E 246E
840 26D7 2461 1547 246F 246E 246E 246E
840 26D6 2461 1546 246F 246E 246E 246E
840 26D5 2461 1545 246F 246E 246E 246E
840 26D4 2461 1544 246F 246E 246E 246E
840 26D3 2461 1543 246F 246E 246E 246E
840 26D2 2461 1542 246F 246E 246E 246E
840 26D1 2461 1541 246F 246E 246E 246E
840 26D0 2461 1540 246F 246E 246E 246E
840 26CF 2460 1546 246F 246E
840 24CE 2460 1545 246F 246E
840 24CD 2460 1544 246F 246E
840 24CC 2460 1543 246F 246E
840 24CB 2460 1542 246F 246E
840 24CA 2460 1541 246F 246E
840 26C9 2460 1540 246F 246E
Symbolic FRUs