v Power Supply P03 – part 90H6629
v Power Supply PP1 – part 24L0728
v Power Supply PP2 – part 24L0728
v AC Input / Battery Charger A01 – part 97H7316
This ends the Procedure.
PWRREG
A power regulator card may be failing.
Attention: To avoid thermal damage to other cards when exchanging regulators,
you must put the EMC shield for the CEC regulator in place before powering on
the system.
Perform any SPCN-PIPs before exchanging parts.
Attention: AC power must be removed from the system before removing or
installing regulator 3.
Note: The C in the SRC (1xxC xxxx) indicates the problem is on the system
processor Frame.
Perform the following to determine the part number for the failing power
regulator:
1. Is the SRC 1xxC xxxx?
Yes No
↓ Go to step 6 on page 574 of this procedure.
2. Find the URC in the following table and exchange the part that is listed for
the system Unit. If the URC is not listed in this table go to step 3 on page 574
of this procedure.
System Unit URCs
URC Location Part number
1108, 1308 R01 21H7763
1109, 1309 R02 21H7763
110B, 130B R04 21H7763
110C, 130C R05 21H7763
110D, 130D R06 21H7763
110E, 1308E R07 21H7763
110F, 130F R08 21H7763
1110, 1310 R09 21H7763
1111, 1311 R10 21H7763
1112, 1312 R11 21H7763
111B, 131B R20 21H7763
111C, 131C M04 23L3613
111D, 131D M07 23L3613
111E, 131E M19 04N5763
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 573