Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9082 I/O processor card detected device error
Perform “SDIOP-PIP16” on page 407.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
9090 Disk unit has been modified after the last known status.
Re-IPL the system. If any reference codes are surfaced, go to “Chapter 2.
Unit Reference Codes” on page 59 and use the new reference code as the
entry point to the problem.
If you cannot resolve the problem, contact your next level of support.
SVCDOCS
9091 Incorrect hardware configuration change has been detected.
Re-IPL the system. If any reference codes are surfaced, go to “Chapter 2.
Unit Reference Codes” on page 59 and use the new reference code as the
entry point to the problem.
If you cannot resolve the problem, contact your next level of support.
SVCDOCS
9092 Disk unit requires initialization before use.
Perform “SDIOP-PIP26” on page 427.
SVCDOCS
B3B7 A permanent I/O processor failure occurred IOP
B3B8 Multi-adapter bridge error detected. MA_BRDG
IOP
B3E1 I/O processor detected a fault condition. IOP
MA_BRDG
B410 to B411 A permanent I/O processor failure occurred STORIOA
B412 Tape/CD or disk bus interface error occurred
Perform “SDIOP-PIP16” on page 407.
FI01107
FI01140
STORIOA
DEVTERM
B935 Unknown hardware detected FI01101
AJDGP01
IOP
MA_BRDG
BE00 I/O processor detected a fault condition. AJDGP01
IOP
FI01104
MA_BRDG
FF3D I/O processor card STORIOA
IOP
FF6D I/O processor detected a recoverable system bus error IOP
ANYBUS
Failing Items
Notes:
1. To determine the failing items, go to “Failing Items” on page 479.
2. To determine the associated part numbers, go to “Type, Model, and Part
Number list” on page 885.
2749, 2767, 2768, 2842, 2843, 284B
130