3. Press the Power button (white) on the control panel.
The Data-Function display shows O? (the international power-off symbol).
4. Press the Power button (white) on the control panel again.
Note: To cancel the power-off operation, do not press the Power button a
second time. Instead, press any other control panel button.
5. The Power On light starts blinking at the fast rate of one blink per second as
the system powers off. The light starts blinking at the slow rate of one blink
per three seconds when the power-off operation is complete.
Does the system power off successfully?
No Yes
↓ This ends the procedure.
6. Perform the following:
a. Press the ↑ or the ↓ button until function 08 is shown in the Function
display.
b. Press the Enter button.
c. SRC A100 8008 is on the Data display.
7. Press the Power button (white) on the control panel.
The Data-Function display shows O? (the international power-off symbol).
8. Press the Power button (white) on the control panel again.
The system powers off, and the Power On light blinks at the slow rate of one
blink per three seconds.
Note: To cancel the power-off operation, do not select function 08. Instead,
press any other control panel button.
This ends the procedure.
Powering Off a System With Multiple Logical Partitions
Determine if the system must be powered off or if only the secondary partition
that you are servicing must be powered off by using the following table as a guide.
The Service Action is: Go to:
A power or system power control network problem. “Powering Off a System with
Multiple Logical Partitions Using
the Control Panel or Primary
Partition’s Console” on page 925.
A processor, system storage or processor clock
problem.
“Powering Off a System with
Multiple Logical Partitions Using
the Control Panel or Primary
Partition’s Console” on page 925.
A problem with any resource owned by the Primary
partition.
“Powering Off a System with
Multiple Logical Partitions Using
the Control Panel or Primary
Partition’s Console” on page 925.
The SRC came from the system control panel. “Powering Off a System with
Multiple Logical Partitions Using
the Control Panel or Primary
Partition’s Console” on page 925.
Data Recovery and General System Information
924
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1