REM_SYS
A problem has occurred in a remote system that is in an HSL OptiConnect loop.
The Service Action Log (SAL) code will attempt to identify the HSL loop number
of the local system and the serial number of the remote system as a portion of the
part description for this symbolic FRU. If the SAL could not identify the serial
number of the remote system then check all the systems which are connected to
the local HSL loop identified in the SAL. Search the SAL of the remote system(s)
for hardware and LIC problems. Correct any problems you find with LIC or
Network Interface Controller (NIC) hardware.
This ends the procedure.
RIOPORT
The system processor has detected an error on the HSL port.
Use the information in the Location column of the Reference Code table and the
information from Locations and Addresses on page 705 to determine the physical
mapping of the information from the Location column.
Check the cabling and connections from the failing item location. Follow the
procedure in Symbolic FRU SIRGCBL on page 588.
RMDEV
A removable media power regulator or device in a migrated expansion tower may
be failing.
See the RMDEV symbolic FRU in the Migrated Expansion Tower Problem Analysis,
Repair and Parts for FRU isolation instructions.
SIADPCD
SIADPCD: High Speed Link I/O bridge card.
The failing component is the HSL I/O bridge card in a system unit base I/O tower,
a FC 5074, FC 5078/0578, or FC 5079 (1.8m expansion tower) I/O expansion tower,
or the Integrated xSeries Adapter Card in an xSeries server.
1. If you a working from the Service Action Log and you know the frame ID
where this failing component is located, then continue with the next step in this
procedure. Otherwise, record the bus number value (BBBB) in word 7 of the
SRC, see Breaking Down The SRC on page 280 for help in determining the
bus number. Search for the bus number in HSM or the System Configuration
Listing to determine which frame or I/O tower contains the failing component.
2. Determine the tower type where the failing component is located and exchange
the FRU indicated using the links to the service information for that FRU.
Symbolic FRUs
582
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals