2. Do you have a SRC 1xxx 4500, 4501, 4502, 4507, or 4513?
No Yes
↓ An incorrect status response was detected during normal operation.
Before calling the UPS provider, unplug and replug the UPS signal
cable connector. If the fault clears, contact UPS provider to fix the UPS.
If the fault does not clear, the problem is in the system unit and you
need to refer to “TWRCARD” on page 601.
3. Do you have a SRC 1xxx 4510?
No Yes
↓ The UPS did not respond to a test request. Call the UPS provider for
service.
4. Were you sent to the UPSUNIT procedure by SRC 1xxx 4503, 4504, or 4505?
No Yes
↓ Call the UPS provider for service. Even though the UPS has been
repaired, when the system is powered on, the old fault was displayed
and reported. Refer to Important UPS Information for further battery
test instructions.
This ends the procedure.
USER
System operator error or user error. See the system operator information.
This ends the procedure.
UX201
The printer definition table may be causing the problem.
Perform the following:
v See the original system message for cause and recovery information about the
error.
This ends the procedure.
UX202
A problem was detected while downloading a device Licensed Internal Code
change to the device.
Perform the following:
v See the original system message for cause and recovery information about the
error.
This ends the procedure.
UY1Z1
Cable problems:
See the IBM Technical Information Manual for information on how to correct cabling
problems. Problems that are associated with noise can cause a workstation to fail
or lose communication with the system for various lengths of time. A motor or any
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 607