4: Configuration Using the Web Manager
EDS4100 4 Port Device Server User Guide 48
Table 4-5. Tunnel – Serial Settings Page
Tunnel –
Serial
Settings Page
Description
Buffer Size Enter the size of the buffer used to receive data on the currently selected
serial line. Range = 1 to 4096 bytes. Default is 2048 bytes. Changing this
value requires the EDS4100 to be rebooted.
Read Timeout Enter the maximum number of milliseconds that the EDS4100 waits for
incoming data on the currently selected serial line. Default is 200
milliseconds.
Wait for Read
Timeout
Select whether the EDS4100 waits the entire Read Timeout value for
incoming data on the serial line. Waiting occurs even if there is data in the
read buffer ready to be processed. The Read Timeout is ignored only
when the read buffer completely fills with data. Choices are:
Enabled = wait the entire Read Timeout value for incoming data on the
serial line.
Disabled = do not wait the entire Read Timeout value for incoming data.
(default)