• 2— Europe Economic Area + extras (EEA+)
• 5— Rest of Europe, Middle East, Africa (RoEMEA)
• 7— Latin America, Asia Pacific (LAD / AP) (+Aus/ NZ)
43 user attendance error messages
Error code Description Action
43.41z Cyan bottle TMC error. See
“Toner meter cycle (TMC) card service
check” on page 268.
43.42z Magenta bottle TMC error.
43.43z Yellow bottle TMC error.
z codes:
• Y— First error, recoverable
• Z— Second error, non-recoverable
80 user attendance error messages
Error code Description Action
80.01 The maintenance kit is nearly low. The backup
roll or fuser page count threshold has been
reached.
See
“Maintenance kit service check” on
page 174.
80.09 The maintenance kit is nearly low. The
user‑selected EWS set point has been reached.
80.11 The maintenance kit is low. The backup roll or
fuser page count threshold has been reached.
80.19 The maintenance kit is low. The user‑selected
EWS set point has been reached.
80.21 The maintenance kit is very low. The backup roll
or fuser page count threshold has been reached.
80.29 The maintenance kit is very low. The
user‑selected EWS set point has been reached.
80.31 Replace the maintenance kit. The backup roll or
fuser page count threshold has been reached.
The fuser may continue to function beyond end
of life.
80.39 Replace the maintenance kit. The user‑selected
EWS set point has been reached. The fuser may
continue to function beyond end of life.
7528
Diagnostic information
166