4-3SectionCommands/Responses
394
Command
0
1B 50
[ESC] P
32
30
0
30
0
4D
M1
3130
2
0
30
3
1
,
2C 41
A0
30 2C
,
36
6
33
31
0D
3
31
17
37
[CR]
33
First word address of window control area: CIO 120
Number of changed words in window control area:
3 words
Screen number (hexadecimal): 10H
(screen No.16 in BCD)
Window X coordinate (hexadecimal): A0H (160 in BCD)
Window Y coordinate (hexadecimal): 63H (99 in BCD)
Checksum: 71H
Reference:  With memory link communication, bit 12 (screen switch strobe), bit 11 (numer-
al setting strobe flag) and bit 10 (character string setting strobe flag) of PT sta-
tus notify bit do not go ON/OFF. It is possible to know them by direct area
changing notify command, numeral input notify command and character
string input notify command.
 When the PT was switched to RUN mode from system menu or error screen,
notification of change in PT notify area (PT operation status: ON) is issued to
the host.
Also, when the PT was switched to system menu or error screen from RUN
mode, notification of change in PT notify area (PT operation status: OFF) is is-
sued to the host.
4-3-19 PT Memory Changing Notify Command (Sent from PT to Host)
Command
Format
1B 53
[ESC]
[CR]
S
0D
4D
Mc1c2 l2
s1 s2
c3
c4 l1
dn1 dn2 dn3 dn4
d11 d12
d13 d14
2C
,
* * * * * * * * * * * * * * * *
* * * * * * * * * * * * * * * *
c
1
to c
4
: First word address of PT memory (4 BCD digits)
0000 to 9999
l
1
, l
2
: Number of words in direct area (2 BCD digits)
01 to 50
d1
1
, d1
2
, d1
3
, d1
4
, ..., dn
1
, dn
2
, dn
3
, dn
4
:
Contents of the direct area (1 to 4 hexadecimal digits)
0 to FFFF
H
It is possible to omit initial zeroes so that there are less than 4
digits.
Individual words of data are delimited by commas.
s
1
, s
2
: Checksum (2 hexadecimal digits)
Response
None
Notifies to the host of the change in PT memory.
Format
Function
Contents of
direct area after
the change

Table of Contents