10.34
9924874 R02 - 2014 RZR XP / XP 4 1000 Service Manual
© Copyright 2013 Polaris Industries Inc.
BATTERY SERVICE
Battery Specifications
Type
Polaris / Johnson Controls 575
Sealed - Maintenance Free
Voltage
12 Vdc
Nominal Capacity
@ 10 HR Rate
30 AH
CCA
575
Nominal Open
Circuit Voltage
12.8 Vdc or more.
Recommended
Charging Rate
1.8A @ 5-10 HR or 6.0A @ 1
HR
NOTE: Never attempt to open the battery. If the seal
is broken, the battery will be ruined and will fail
within a few weeks.
General Battery Information
WARNING
CALIFORNIA PROPOSITION 65 WARNING:
Batteries, battery posts, terminals and related
accessories contain lead and lead compounds, and
other chemicals known to the State of California to
cause cancer and birth defects or other reproductive
harm. WASH HANDS AFTER HANDLING.
WARNING
Battery electrolyte is poisonous. It contains acid!
Serious burns can result from contact with the skin,
eyes, or clothing.
ANTIDOTE:
External: Flush with water.
Internal: Drink large quantities of water or milk. Follow
with milk of magnesia, beaten egg, or vegetable oil. Call
a physician immediately.
Eyes: Flush with water for 15 minutes and get prompt
medical attention.
Batteries produce explosive gases. Keep sparks, flame,
cigarettes, etc. away. Ventilate when charging or using
in closed space. Always shield eyes when working near
batteries.
Keep out of reach of children.
1. Check battery voltage with a volt/ohm meter. A fully
charged battery should be 12.8 V or higher.
2. If the voltage is below 12.6 V, the battery will need to
be recharged (see “Charging Procedure”).
To service a Maintenance Free battery:
3. Remove battery from the vehicle (see Chapter 2).
4. Test battery with a voltage meter or load tester to
determine battery condition. This will determine the
length of time required to charge the battery to full
capacity. Refer to OCV table (see “OCV - Open
Circuit Voltage Test”).
5. Charge the battery as recommended (see “Charging
Procedure”).
ELECTRICAL

Table of Contents