4.1 Activating the data transfer between the PLC and NCK
Function
Data transfer from/to NCK with the following properties can be started via the PLC:
● Data transfer from the hard disk to or from the NCK (workpiece directory, part program,
etc.) using job lists.
● The "Job list" function is used in HMI-Advanced to process part programs - e.g. loading,
unloading, selecting or executing from the hard disk.
By means of the interface between the PLC and HMI in DB19, the PLC issues jobs to the
HMI that initiate a data transfer between the HMI (PCU hard disk) and NCK.
Specifying the user control file: DB19.DBB16 (PLC → HMI)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Always = 1 PLC index for the user control file ; value: 1 - 127
Specifying the job list: DB19.DBB17 (PLC → HMI)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
PLC line offset in the user control file; value: 1 - 255
Job byte of PLC: DB19.DBB13 (PLC → HMI)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Selection Load Unload
Acknowledgment byte from HMI for the current data transfer status:
DB19.DBB26 (HMI → PLC)
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Selection Load Unload Active Error OK res. PLC
NOTICE
Machine manufacturer
See machine manufacturer's specifications.