Diagnostics and service
5.6 Action log
HMI Advanced (IM4)
152 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
5.6 Action log
5.6.1 Setting the action log
Overview
The "action log" function can be used to log operating sequences. By default, if the action log
is enabled, the data that can be logged are recorded. The action log setting is password-
protected (access level 3: end user).
Using the operating area "Start-up" → "HMI" → "System Settings,“ select which actions of the
control should be logged in the "Action log settings":
Figure 5-7 Action log settings
Logging on/off
Additional settings:
The path of the log file is permanently set and cannot be changed.
File size of log file:
in bytes
Transmission Write interval:
− 1: The log is only saved to hard disk upon request,
e.g. trigger, (default setting).
> 0: The longest waiting time in seconds before a log file
is saved on hard disk.
Program status when an
alarm occurs:
Alarm number entry separated by a comma: The alarms
entered here are immediate triggers for immediately
saving the current action log on the hard disk.

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals