Configuring the system
2.4 PCU 50.3 with SITOP UPS module
PCU-Basesoftware (IM8)
46 Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
2.4 PCU 50.3 with SITOP UPS module
Conditions
PCU-Basesoftware WinXP V08.00.00 or higher for USB port
HMI Advanced of V07.01.00 or higher
SITOP software, version 2.5.2.4or higher is installed:
SITOP software is available to download from: www.automation.siemens.com/sitop.
SITOP monitor/configuration program is installed:
To enable this, the SITOP software must be copied to the E:\SITOP directory set up on
the PCU. This directory already contains PCU tools required for shutdown on the SITOP
UPS. If this directory does not exist in an older version of the PCU-Basesoftware, it must
be created so that it will be compatible for any subsequent updating of the PCU-
Basesoftware.
UPS USB driver for Windows XP is installed:
Installation is described in the relevant SITOP documentation. The documentation is part
of the SITOP software download package.
The SITOP UPS hardware is connected.
NOTICE
The SITOP software version 3.1.0.6 can be operated with PCU-Basesoftware
V08.02.00.01 or higher subject to the following conditions:
SITOP software must not be installed as a Windows service, but must be started as
a normal application (as described in the chapter titled "Starting and configuring the
SITOP monitor").
The SITOP service prevents the correct switch-off procedure being performed on the
SITOP UPS module when PCU-Basesoftware is installed.
Application
If the supply voltage at the PCU dips, the SITOP UPS modules below could maintain
operation for a limited period if a backup battery is being used, allowing the PCU to be
properly shut down before the battery is exhausted:
Name Order number (MLFB)
SITOP POWER DC UPS module 15 (USB interface) 6EP1931-2EC41
Note
Information about the test environment for machine OEMs
The "SITOP UPS" function has been tested in the standard configuration of HMI Advanced.
When installing add-on or OEM software components, the shutdown procedure of the
complete system has to be checked by the operator.

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals