Configuring environment
6.3 Storage structure of configuration files
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
6-9
\cycles\ico (Display image directory – contains only subdirectories for
each resolution)
\cycles\ico\ico640 Directory for the display images of resolution 640*480 as
.bmp or .bin
\cycles\ico\ico800
\cycles\ico\ico1024
For dialogs, which are assigned to other operating areas:
\hmi\proj
\hmi\lng\...
\hmi\ico\...
In the PROGRAM operating area, the entire \cycles or \hmi directory is copied from the USB
memory to the /user/sinumerik directory on the CF card.
6.3.2 HMI Advanced
Overview
When using HMI Advanced, no control file entries are required.
The directories are searched for the configuration files in the specified order. If files of the
same name are stored in different directories, then the first file detected according to the
search strategy is interpreted.
Test on a PG/standard PC
To test the configured dialogs on a PG/standard PC, the following conditions apply:
You have installed the PC version of the HMI Advanced software on your PC/PG.
The directory structure is the same as on HMI Advanced.
The error log is generated in: \DH\COM.DIR\ERROR.COM
Storing the alarm text files
Alarm text files are stored in the following directory: \DH\MB.DIR\
File name: ALUC_
xx
.COM
References: HMI Advanced Startup Manual

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals