EasyManuals Logo
Home>Siemens>Control Unit>SINUMERIK

Siemens SINUMERIK Commissioning Manual

Siemens SINUMERIK
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
Parameterizing machine data
3.1 Handling machine data via the HMI
HMI Advanced (IM4)
94 Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
Filter criteria
The following table shows the criteria for displaying machine data in the order in which they
are evaluated:
Criterion Checks
1. Access authorizations If the level of access authorization is not sufficient, the MD is not
displayed.
Otherwise criterion 2 is checked.
2. Display filter active The MD is always displayed when the filter is not active.
Otherwise criterion 3 is checked.
3. Expert parameters The MD is not displayed if expert parameter bit is set and expert
parameters is not selected.
Otherwise criterion 4 is checked.
4. Display groups If at least one group bit is both set and selected in the display filter,
criterion 6 is checked.
Otherwise criterion 5 is checked.
5. All others If none of the group bits is set and "All others" is selected in the display
filter, then criterion 6 is checked.
If none of the group bits is set and "All others" is not selected in the
display filter, then the MD is not displayed.
6. Indices from ... to ... If the index check is selected and the index of an array is within the
chosen range, then the MD is displayed.
If the index check is selected and the index of an array is not within the
chosen range, then the MD is not displayed.
If the index check is not selected, then the MD is displayed.
3.1.2 Creating user views
User views
User views are user-specific groups of machine data. They are used to call all relevant
machine data in a certain operating state from various areas for processing.
Overview of machine data
You can include the following machine data in the user view:
General machine data
Channelspecific machine data
Axis-specific machine data
General setting data
Channel-specific setting data
Axis-specific setting data

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK
CategoryControl Unit
LanguageEnglish

Related product manuals