Configure hotkeys and PLC keys
4.5 List of selectable states
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
4-19
4.5 4.5 List of selectable states
4.5.1 Selectable states in HMI Advanced
Overview
In general, the following conditions apply to all tasks in HMI Advanced:
No configuration: Maintains current state.
Configuration with 0: The basic state of an operating area is activated.
"Machine" operating area
In the Machine operating area, the status is always dependent on the status of the machine
(AUTO, MDA, JOG, REF). The following can be selected via the PLC key:
● The main screen for the relevant mode
State BAG Machine function Display
0 JOG REF JOG/REF main screen
0 JOG none JOG main screen
0 JOG REPOS REPOS main screen
0 MDI none MDA start screen
0 MDI TEACH MDA/Teach main screen
0 MDI REF MDA/REF main screen
0 AUTO none Auto main screen
● The main actual value screens for each mode (softkey vertical 6)
State BAG Machine function Display
10 JOG none Zoom actual values JOG
20 MDI none Zoom actual values MDA
30 AUTO none Zoom actual values Auto
● Possibly still in JOG / MDA
Switching between the WCS and MCS is possible via the PLC.
State BAG Machine function Display
60 JOG none Handwheel selection JOG
70 JOG none Increment selection JOG
80 MDI none Handwheel selection MDA