HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
133
Diagnostics and service
5
5.1 Installing HMI software on a PG/PC
Requirements
Target system: PG or PC with 600 MHz / 256 MB RAM
Available hard disk space: 500 MB
Operating system: Windows XP Professional
MPI driver: Version 6
NC connection (SINUMERIK powerline) CP5511
CP5611
NC connection (SINUMERIK solution line): Network connection (Ethernet)
"Small fonts" must be selected under "Control Panel → Display, Settings".
Software
• Name
HMI-Advanced for PC/PG
• Installation language
German/English
• Distribution medium
CD
• Can be uninstalled
Yes
Operating sequence
1. Insert the CD in the CD drive
2. Start setup.exe
3. Select language
4. Specify the target directory: Any
5. For SINUMERIK powerline, select:
– Online with communication to NC
– The system asks whether you wish to install the MPI drivers
– Local without communication to NC, with NC simulation
6. For SINUMERIK solution line, select:
– Online with communication to NC
7. The system lists all the entries you have made