Programming
2.6 Methods
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
2-69
Example
OUTPUT(NC1) ; Only the variables of the original version are
made available in the OUTPUT block.
OUTPUT(NC1,1) ; The variables of the original version and the
expansions with version identifier 1 are made
available in the OUTPUT block
The OUTPUT block for the original version does not need a version identifier, however you
can specify it with 0. OUTPUT(NC1) is equivalent to OUTPUT(NC1,0). Version identifier n in
the OUTPUT block includes all variables of the originals 0, 1, 2, ... up to and including n.
Programming with version identifier
//M(XXX) ; Version 0 (default)
DEF var100=(R//1)
DEF var101=(S//"Hello")
DEF TMP
VS8=("GC")
PRESS(VS8)
GC("NC1")
END_PRESS
OUTPUT(NC1)
var100",,"var101
END_OUTPUT
; ************ Version 1, extended definition ***************
//M(XXX)
DEF var100=(R//1)
DEF var101=(S//"Hello")
DEF var102(1)=(V//"HUGO")
DEF TMP
VS8=("GC")
PRESS(VS8)
GC("NC1")
END_PRESS
...
OUTPUT(NC1) ; Original and the new version in addition
var100","var101
END_OUTPUT
...

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
InterfaceEthernet, PROFIBUS, PROFINET, USB
Programming LanguagesDIN/ISO
DisplayTFT color display
CompatibilitySiemens drives and motors
SoftwareSINUMERIK Operate
Control Unit TypeCNC (Computer Numerical Control)
Safety FunctionsIntegrated safety functions up to SIL 3/PLe

Related product manuals